製品パラメーター
| パラメータ | Model:HF-Sponge-1A1B-Hydrophilic Sponge |
|---|---|
| 注入率 | 50–1000 g/s |
| 原材料比率 | Hydrophilic modified polyether polyol : Isocyanate (TDI/MDI) = 100:85–95 |
| タンク容量 | 100 / 150 L |
| ミキシングヘッド速度 | 5000–9000 r/min |
| 計量精度 | ≤±0.3%(Full range) |
| タンク構成 | 1A1B two-component independent temperature control |
| 材料の温度制御 | Tank A: 25–45℃; Tank B: 20–40℃ |
| Foaming Pressure | 0.5–2.0 MPa |
| 洗浄システム | Sterile circulating cleaning + air purge cleaning |
| パワー | 5.5–8 kW |
| 制御システム | PLC + touch screen + multi-formula storage |
| 適用システム | Medical-grade polyether polyol + Medical-grade isocyanate |
| 保証 | 1年 |
| 認証 | CE, ISO9001, Biocompatibility Certification |
アプリケーション・シナリオ
Specially designed for the pouring molding of hydrophilic polyurethane sponge. It is suitable for the production of various hydrophilic sponges such as wound dressings, incontinence care products, maternal and infant supplies, and beauty sponges. It meets the core requirements of hydrophilic sponges for high water absorption, high water retention, softness and non-irritation, and can quickly absorb and lock liquid. It complies with the strict production standards and quality control requirements of the hydrophilic sponge industry, ensuring the safety and reliability of hydrophilic sponge use.
コアの利点
1A1B single hydrophilic formula design, easy operation, efficient production changeover, suitable for small-batch and multi-specification precision production of hydrophilic sponges, ensuring stable hydrophilic performance and improving product consistency.
Dynamic full-range high-precision metering ensures uniform density and thickness of hydrophilic sponge, fine foam cells, high open cell ratio and excellent hydrophilicity, which can quickly absorb and lock liquid.
The hydrophilic modification system has outstanding characteristics. The hydrophilic sponge wets quickly after contacting liquid without liquid rejection. It has strong water retention and liquid is not easy to seep out under pressure, suitable for various special application scenarios.
Precise temperature control and foaming pressure control ensure uniform foaming and stable foam cell structure. The hydrophilic sponge has moderate softness, comfortable and non-irritating contact with human skin, suitable for long-term use.