Blog · November 22, 2026

PU Mixing Ratio Drift: Why It Happens and How to Trace It

A ratio that passed acceptance testing in spring can be feeding a different one by autumn. Polyurethane mixing ratio drift is rarely one failed part. It is the sum of small physical changes: pump clearances opening, material temperature moving a few degrees, a day tank running low, a polyol lot arriving with a different viscosity, and a controller reporting motor rotation rather than delivered mass. None of these changes announce themselves. The parts do, as a hardness shift, a slow cure, a rising reject rate, or a surface defect that appears without any formula change. The sections below follow each mechanism to a check you can run on a live line, in the order that isolates the cause fastest.

What Ratio Drift Looks Like Before You Measure It

Ratio is a mass relationship between what the two pumps actually deliver, not the number typed into the recipe. At a 100:40 setpoint, every 100 kg of polyol should meet 40 kg of isocyanate at the mixing head. The recipe screen can display 100:40 for years while the delivered mass ratio moves, because the setpoint is a command and the pumps decide what happens next.

Shot weight alone will not reveal it. When one pump loses output, total shot weight falls, and the usual correction is to trim shot time or injection pressure. That adjustment restores the total and leaves the ratio roughly where it was. Many ratio problems survive weeks of weight-based quality control for exactly this reason.

Drift also has a time signature, and the signature narrows the cause faster than any single instrument reading.

Drift pattern Typical origin First check
Moves at the start of each shift, then settles Cold material, thermostat recovery, cold suction line Tank, hose and head temperatures at the first shot
Drifts steadily within a single shot One pump cavitating or slipping as back pressure rises Discharge pressure and pump sound during the shot
Drifts from a full day tank to a nearly empty one Falling static head, entrained air, filler settling Ratio at tank start and at tank end
Moves slowly across weeks Pump clearance wear, loading filters, meter drift Gravimetric catch test against a stored baseline
Jumps once after a maintenance event Coupling or pump replacement, seal change, calibration error Mechanical setup record and calibration sheet
Steps once, then holds steady New polyol or isocyanate lot with different viscosity Lot certificate and viscosity at reference temperature

Once a catch test exists, express drift as a normalized deviation rather than a vague complaint. With a setpoint of 100:40, the ratio is 2.50 kg of polyol per kg of isocyanate. A catch test that weighs 100.0 kg of polyol against 41.6 kg of isocyanate gives a measured ratio of 2.404.

Deviation = (2.404 – 2.500) / 2.500 × 100 = -3.8%

The polyol side is on target and the isocyanate side is about 4% high against the recipe. In an MDI-based shoe-sole or elastomer system, that shift normally raises hardness and lowers elongation, and it can add surface defects because the excess isocyanate reacts with any available moisture. The number matters because it tells you which side to investigate, not because a single percentage applies to every formulation.

a1

Pump Slip and Wear in Volumetric Metering

A gear or piston pump displaces a fixed volume per revolution minus internal leakage, usually called slip. Slip grows as discharge pressure rises and shrinks as viscosity rises. The important detail is that slip is not symmetric. Polyol and isocyanate differ in viscosity, lubricity, and abrasiveness, so the two pumps wear at different rates and respond differently to the same back pressure.

That asymmetry is the engine of long-term drift. A filled polyol carrying calcium carbonate or glass bead abrasive slowly opens the clearance on the polyol gear set, while the isocyanate side stays dimensionally tighter but becomes vulnerable to crystallization and scoring. After a few months, the same command produces a different delivered ratio. Filter loading and mixing-head orifice wear add to it by raising back pressure on both sides unequally.

Piston and plunger pumps drift differently. Their displacement is more rigid, but inlet and outlet check valves wear, and a leaking check valve produces a loss that is large at low output and small at high output. The ratio error therefore changes with the flow rate you run, which is why a machine that tested clean at one operating point can fail at another.

Closed-loop servo control holds shaft speed precisely. It does not, by itself, know what the pump actually delivered. One design response from Haifeng Polyurethane Machinery pairs servo-driven closed-loop metering with flow-error compensation, and the LJJ series low-pressure machines are specified at ±0.5% metering accuracy. Compensation reduces the drift rate, but it acts only on the error its sensors can see, which is why a gravimetric baseline still has to be kept.

Metering architecture decides how much of a ratio error a machine can hide. <Polyurethane Foam Machine: Types, Working Principle and Applications> covers how metering and mixing are arranged across machine types.

a3

Temperature and Viscosity Change the Delivered Mass

A volumetric pump meters volume, and mass equals volume times density. Temperature moves both terms, in opposite directions on different components. Warmer material has lower viscosity, so slip increases and delivered volume falls. Warmer isocyanate also has lower density, so the same volume carries less mass. If one component is heated and the other is not, the ratio responds to ambient conditions, seasonal temperature, and the distance between the day tank and the mixing head.

This is the most common cause of a ratio that looks stable in the afternoon and wrong on the first shift. Overnight cooling changes both viscosity and density, and the thermostat needs time to bring the circuit back.

Two boundary conditions matter. First, the effect depends on which side is conditioned: a machine holding polyol at 25 °C and isocyanate at 40 °C is running a deliberate thermal asymmetry that must be reflected in the mass ratio, not corrected away. Second, a biased thermocouple is worse than no control, because it holds the wrong temperature steadily and the log looks perfect while the delivered mass is off.

Practical checks are simple. Record tank, hose, and mixing-head temperature for both components at the first shot and at steady state. Then plot ratio deviation against ambient or material temperature for a week. A correlation is strong evidence, and it points to conditioning rather than to the pump.

a6

Tank Level, Degassing and Cavitation at the Pump Inlet

Inlet conditions change continuously through a shift, which makes them a natural source of slow drift. A full day tank provides more static head at the pump inlet than a nearly empty one. As level falls, the net positive suction head margin shrinks, and a pump that was running clean begins to cavitate intermittently. Delivery drops, and the drop depends on level, so the ratio appears to wander.

Entrained air produces a similar but more persistent error. Gas compresses, so a volumetric pump moving an aerated material delivers less mass per stroke than the same pump moving degassed material. Vacuum degassing on the tank helps, but the vacuum level itself can move as filters load or a seal wears. A vacuum gauge that nobody reads is a common blind spot.

Filled systems add density stratification. When a mineral-filled polyol stands in a tank, the filler settles and the material drawn from the bottom is denser than the material at the top. The pump is behaving correctly and the delivered mass ratio still changes through the batch.

The signature to look for is ratio deviation that tracks tank level, drum level, or time since the last refill. Measure a catch test at the start and at the end of a drum. If the two results differ, the pump is not the first suspect, the tank is.

a9

Material Lots, Fillers and Moisture

Some ratio changes are not machine drift at all. They are material changes that the machine faithfully reproduces. Polyol hydroxyl value and viscosity vary within specification from lot to lot, and a ratio optimized around one lot may sit slightly wrong for the next. The machine did not move; the reference did.

Moisture is the more damaging variant. Water reacts with isocyanate and consumes it, so the effective ratio at the mixing head shifts, and the reaction produces carbon dioxide and urea that can leave voids or gel particles. In MDI systems stored cold, crystallization adds solid particles that restrict flow, raise pump pressure, and cause under-delivery on the isocyanate side.

Filled and high-viscosity systems need their own attention, because wear and settling dominate over months rather than weeks.

Elastomer and high-viscosity systems put most of the drift risk into viscosity and temperature control rather than into the mixing head. <Guide to Low-Pressure Foaming Machines for PU Elastomers> covers low-pressure machine configuration for elastomer systems.

The check is documentary as much as mechanical. Keep a retained sample of each incoming lot, record viscosity at a fixed reference temperature, and review the NCO content certificate. When a step change in ratio coincides with a lot change, treat it as a material issue first and adjust the recipe deliberately, with a note, rather than by quietly trimming a pump factor.

What the Encoder and Flowmeter Cannot See

Most machines report a ratio, and the number comes from one of five sources. Knowing which one you are trusting tells you what the reported ratio can prove.

What the machine reports What it measures What it can miss
Motor revolutions or encoder counts Shaft rotation Coupling slip, pump slip, cavitation
Volumetric flowmeter Volume at the meter’s calibration condition Viscosity and temperature effect on the meter factor, entrained air
Coriolis mass flowmeter Mass flow at the sensor Sensor drift, deposit fouling, expired calibration
Discharge pressure gauges Hydraulic condition Whether fluid actually moved
Gravimetric catch test with separate weighing Delivered mass of each component over a defined period Nothing beyond the sampled operating point

Two failure modes hide behind those sources. A worn flowmeter factor keeps reporting a clean ratio while the delivered mass has moved. And a ratio computed from two independent meters multiplies both errors, so agreement between the two displays is not confirmation.

Pressure belongs in this section too. Higher back pressure, from a loaded filter, a cold hose, or a partly blocked nozzle, increases slip, and it increases it more on the lower-viscosity side. A filter that loads gradually over weeks therefore presents as ratio drift with no electronic fault at all. This is why a machine validated at one pressure and flow rate needs revalidation when the operating point changes.

High-pressure impingement and low-pressure mixing handle pressure, recirculation and ratio control quite differently. <High Pressure vs. Low Pressure Polyurethane Foam Machine: How to Choose the Right One for Your Production> compares the two architectures for production selection.

a16

A Diagnostic Sequence for Tracing the Drift

Work through these steps in order and stop at the first one that produces a clear answer.

  1. Run a gravimetric catch test at production temperature and production flow, weighing each component separately. Confirm the drift exists before touching any parameter.
  2. Normalize the result to mass ratio and record the conditions at the same time: tank levels, material temperatures, suction and discharge pressures, vacuum level, and filter differential pressure.
  3. Classify the time signature using the pattern table. Within-shot drift points to slip and back pressure, shift-level drift points to temperature, drum-level drift points to inlet conditions, and month-level drift points to wear.
  4. Check the mechanical baseline: pump running hours, coupling and belt condition, suction strainer condition, and any change in pump sound. Cavitation has an audible signature that operators usually notice before the data does.
  5. Check thermal symmetry: both components at tank, hose, and head, compared with the commissioning record. A single drifted thermocouple explains a surprising number of cases.
  6. Check the material record: lot number, viscosity at reference temperature, NCO certificate, moisture exposure, and settling in filled systems.
  7. Verify the measurement chain last, against a mass standard. If the meters were the problem, steps one to six will have looked normal, which is itself diagnostic.

Two outcomes deserve a separate response. A step change after maintenance is almost always mechanical or a calibration entry error, so recheck the setup record before recalibrating. A one-way trend over months with stable conditions is wear, and recalibrating a worn pump only resets the baseline until the next interval.

Holding the Ratio Over Months of Production

Drift cannot be eliminated, only detected early. The practical approach is to make the ratio visible on a schedule that matches how fast your equipment wears, and to tie each check to a defined action.

Check Interval Action trigger
Gravimetric catch test at production flow Commissioning, after any pump, seal, hose or meter change, then on a fixed schedule Deviation beyond the machine’s specified metering accuracy
Ratio trend log against temperature and tank level Every shift Repeatable correlation with a controllable variable
Pump running hours and filter differential pressure Weekly Trend toward the maintenance limit before quality moves
Viscosity and NCO review for incoming lots Every lot Step change in ratio coinciding with a lot change
Mass-standard verification of the meters Fixed calibration interval Disagreement between meters and catch test

Three habits make the schedule work. Keep the commissioning catch test as a written baseline with its temperatures and pressures, so later tests are comparable. Record the drift direction, not only the magnitude, because one-sided drift points to one pump. And define the alarm threshold in advance, using the machine’s specified accuracy as the reference rather than a number chosen after the first reject.

Beyond that, the decision becomes commercial. A pump set approaching end of life can be recalibrated repeatedly, but each recalibration shortens the next interval and the trend becomes visible in the reject rate before it is visible in the ratio log. Replacing the pump and re-establishing the baseline usually costs less than a quarter of drift-driven scrap.

Get the Ratio Back Under Control

If you are chasing a drift you cannot explain, send the details in a form the diagnosis can actually use: polyol and isocyanate system, target ratio and how it is expressed, measured deviation and when it appears, pump type and running hours, tank, hose and head temperatures, calibration method and date, vacuum and filter differential pressure, and whether the change was gradual or a step.

Email info@haifeng-automation.cn or message WhatsApp 86 13566296633 with those figures, and the Haifeng Polyurethane Machinery team can compare them against the metering specification of the machine you are running and tell you which side of the system is most likely responsible.

FAQ

How often should the mixing ratio be verified?

Set the interval from wear rate rather than from habit. Run a gravimetric catch test at commissioning, after any pump, seal, hose, or flowmeter change, and then on a fixed schedule that shortens if two consecutive tests show movement in the same direction. Between tests, keep per-shift records of temperature, tank level, suction and discharge pressure, and filter differential pressure. Those records show whether the drift tracks a controllable variable. Filled polyol systems and high-duty lines usually need a shorter interval than clean unfilled systems running single shifts.

Can closed-loop ratio control stop drift completely?

No. Closed-loop control corrects the error its sensors report, so it reduces the drift rate and removes some operator dependence. It cannot correct wear that the encoder cannot see, a flowmeter whose factor has moved, a biased thermocouple, or a material property change. That is why a mass-based catch test remains the reference even on a fully compensated machine. The loop and the catch test answer different questions: the loop controls the process, the catch test proves the delivered mass.

Why does the ratio only drift at start-up?

Start-up is when temperature, degassing, and inlet conditions are furthest from steady state. Material sitting overnight in a cold hose is more viscous, the thermostat may not have recovered, and a suction line with residual gas delivers less mass per stroke. Log temperature at the first shot against steady-state temperature and check the recirculation time before the first pour. If the first-shot deviation closes after a defined warm-up period, the fix is conditioning time, not a pump adjustment.

Does higher discharge pressure change the mixing ratio?

Yes, through slip. Higher back pressure increases internal leakage in the metering pump, and the leak is larger on the lower-viscosity side. Because filter loading, hose temperature, and nozzle wear all raise back pressure gradually, a pressure change that nobody recorded can present as unexplained ratio drift. Watch filter differential pressure and mixing-head pressure as trend data, and revalidate the ratio after any change to nozzles, filters, or hose length.

Which side usually drifts first?

It depends on the material system. Filled and abrasive polyol usually wears the polyol pump first, so delivered polyol falls. Low-viscosity or moisture-exposed isocyanate tends to drift first through crystallization, check-valve leakage, or partial blockage, which also reduces delivery. The direction of the deviation in your catch test therefore identifies the suspect side faster than a visual inspection, which is why the test should always weigh both components separately.

If you’re interested, check out these related articles:

How to Design a PU Shoe Factory Layout
Phenolic Sandwich Panel Production Line vs PU/PIR Panel Line: Key Differences for Factory Investors
Glass Wool Sandwich Panel Production Line: Applications, Advantages and Production Challenges
Energy Consumption of PU Shoe Production Lines

Related Posts