Blog · November 10, 2026

How to Calculate PU Component Flow Rates from Output and Ratio

Component flow rates come from one division and one multiplication. Divide each part of the mix ratio by the sum of all parts, then multiply by the total output you want at the mixing head. A 100:45 ratio running at 240 g/min delivers 165.5 g/min of polyol and 74.5 g/min of isocyanate, not 100 g/min and 45 g/min. The arithmetic is simple enough to do on a calculator, yet ratio faults usually trace back to a calculation that used the wrong denominator, a ratio written in the opposite order, or a nominal pump displacement standing in for a measured mass flow. Getting the numbers right before the pump is specified is cheaper than finding the error in a rejected batch.

What Total Output and Mixing Ratio Actually Tell You

Total output describes the combined mass leaving the mixing head per unit of time, with both components added together. The mixing ratio describes how that combined mass splits between the components. Neither number on its own tells you what either pump should deliver, because the split depends on the sum of the parts, not on the total.

A ratio written as 100:45 uses parts, not percentages. The polyol is not 100 percent of anything, and the isocyanate is not 45 percent. The denominator is 145, and each component’s share is its part divided by that sum. Reading 100:45 as two percentages is the first and most common error, because the two figures look like a formulation recipe and a parts count at the same time.

Three conventions can change the answer without changing a single digit. The first is order: some data sheets write polyol first, others write isocyanate first, and a few label the isocyanate side as A. The second is basis: ratio by weight and ratio by volume are different numbers for the same formulation. The third is meaning: mix ratio by weight is what the pumps must deliver, while isocyanate index is a stoichiometric relationship used to design the formulation. They are related but not interchangeable, and a machine set to an index value will not deliver the weight ratio unless someone has converted it.

On the machine, the ratio is the outcome of two independent metering systems. When a controller holds ratio, it adjusts both pumps together as the output setting changes. When an operator trims one pump to correct a shot weight, the ratio moves with it. That coupling is why the calculation and the machine setting have to be checked against each other rather than treated as two separate tasks.

The Component Flow Formula Worked Through

For any number of components, the mass flow of one component is its part divided by the sum of all parts, multiplied by total output:

Q(component) = Q(total) × parts(component) / sum of all parts

The same relationship works for two, three or four components. A 2K system with a 100:45 ratio at 240 g/min splits as follows.

Component Parts by weight Fraction of total Mass flow at 240 g/min
Polyol 100 0.690 165.5 g/min
Isocyanate 45 0.310 74.5 g/min
Combined 145 1.000 240 g/min

Add the two component figures back and you return to 240 g/min, which is the check most people run. It is also the check that fails to catch the expensive mistake. Invert the order and you get 74.5 g/min of polyol and 165.5 g/min of isocyanate. The sum is still 240 g/min, the total output looks correct on the display, and the mixture that comes out carries roughly one third of the isocyanate it needs. A total-output check cannot detect an inverted ratio; only a component-level weight check can.

Multiplying by 60 turns the same figures into consumption: 9.93 kg/h of polyol and 4.47 kg/h of isocyanate, or 14.4 kg/h combined. Those are the numbers that size day tanks and drive drum orders, and they are also the numbers to compare against the machine’s flow trend at the end of a shift.

Converting the flow rate into kilograms per hour is what connects the mixing head to the rest of the plant, because tank refills, drum orders and shift output all use the same unit. <Continuous PU Foam Line Capacity Guide: How Much Foam Can One Line Produce?> covers how line capacity is calculated once output per minute is known.

For a 10 kg combined batch, the split is 6.90 kg of polyol and 3.10 kg of isocyanate. Batch figures matter when a plant buys one component in drums and the other in intermediate bulk containers, because the two containers empty at very different rates and a line can run out of the smaller component while the larger one still looks comfortable.

a1

Converting Weight Ratio into Volumetric Pump Output

Positive displacement metering pumps move volume, not mass. A piston pump delivers its displacement per stroke, a gear pump delivers a fixed volume per revolution, and both are rated in cubic centimetres. The weight ratio from the formulation has to be converted before it can be compared with pump capacity.

Dividing each mass flow by the component density at process temperature gives the volumetric flow:

Q(volume) = Q(mass) / density

With a polyol reading 1.05 g/cm³ at the tank temperature and an isocyanate reading 1.23 g/cm³, the 240 g/min example becomes 157.6 cm³/min of polyol and 60.6 cm³/min of isocyanate. The volume ratio is 2.60:1, while the weight ratio is 2.22:1. Both describe the same formulation, and entering one where the controller expects the other produces a mixture that is wrong by a wide margin.

Density is not a constant. It falls as the material warms, so a volumetric setting established at ambient temperature no longer delivers the same weight ratio at 60 °C. This is one reason a machine with weight-based closed-loop control and a machine with fixed volumetric settings behave differently on the same formulation: the volumetric machine holds a volume ratio while the material’s density moves underneath it.

Filled systems add a second problem. Filler settles in the tank, so the density near the bottom is higher than at the top, and the pump meters whatever happens to sit at its inlet. Agitation and recirculation reduce the variation; neither removes it. When a filled formulation shows a slowly drifting ratio with no pump fault, the tank is often the place to look.

a5

Where the Calculation Breaks Down at Low Output

The formula stays correct at any output. What changes is how much a fixed error in one component matters. Every metering system has error sources that are roughly constant in absolute terms: check valve leakage, pump slip, a small amount of dead volume in the mixing head, and the fraction of a second when the valves are still seating.

At 240 g/min, the isocyanate flow is 74.5 g/min, so a 3 g/min absolute loss is a 4 percent error. At 60 g/min, the same 3 g/min loss is a 16 percent error, and the delivered ratio is closer to 100:38 than 100:45.

Total output Isocyanate flow at 100:45 Fixed 3 g/min loss Relative error on isocyanate
400 g/min 124.1 g/min 3 g/min 2.4%
240 g/min 74.5 g/min 3 g/min 4.0%
120 g/min 37.2 g/min 3 g/min 8.1%
60 g/min 18.6 g/min 3 g/min 16.1%

That is the mechanical reason small shots and low output settings are harder than high output, and it is a sizing problem rather than an operator problem. It cannot be corrected by more careful weighing, because the loss happens downstream of the pump.

Three practical consequences follow. First, the small component needs its own pump sized so the lowest flow you actually run stays inside its controllable band, not merely inside its rated range. Second, the mixing head and the lines feeding it hold a volume that must be purged before a short shot is representative, which is why the first shots after a stop are the least reliable. Third, a line that switches between several hundred grams per minute and a few grams per minute usually needs either two machines or a documented lower output limit.

Required and optional measures should be separated here. A pump sized for the minimum flow is required for the result. A servo-driven closed-loop metering system with real-time flow compensation reduces the error, but it does not remove the need for the sizing decision, because the loop corrects what it can measure and the smallest flows are the hardest to measure.

Haifeng Polyurethane Machinery specifies ±0.5 percent metering accuracy for its LJJ series low-pressure foaming machines. That figure describes steady metering at a set output under stated conditions; it does not mean the delivered weight ratio stays within ±0.5 percent of target at any output or after any material change. The ratio still has to be verified at the flow rates you run.

a11

Turn-down is a machine selection question as much as an arithmetic one, because a pump that holds ratio at 400 g/min may not hold it at 60 g/min. <The Ultimate Guide to Low-Pressure Foaming Machines for PU Elastomers> covers low-pressure metering configurations for elastomer work.

Checking the Calculated Ratio on the Machine

A calculation only describes what should happen. The machine check tells you what does happen, and it takes about twenty minutes at two output settings.

  1. Set the machine to a production output and let it run until temperatures and pressures are stable.
  2. Purge one component into a tared container for a fixed time, weigh it, and convert the result to grams per minute. Repeat for the other component.
  3. Compare the measured component flows with the calculated values, and compare the measured ratio with the target ratio.
  4. Repeat at the lowest output you actually run, then again after any material lot change, pump service or seal replacement.

Weighing each component separately is necessary when you need the ratio itself, because a combined shot weight only confirms the total. A combined shot remains useful as a fast daily check: if the total drifts while the ratio setting has not moved, the change usually comes from temperature, density or pump wear rather than from a control fault.

Machine displays deserve a note. A closed-loop system showing instantaneous ratio is reporting what its flow meters measure, and flow meters are a relative reference that can drift with viscosity and temperature. The weight check is the physical reference, so when the display and the scale disagree, the scale wins and the meter needs calibration.

A ratio that has drifted shows up first as weight or hardness variation, and the cost only becomes visible when parts are rejected. <Polyurethane Foam Machine Types: The Scrap Cost of Inaccurate Metering> covers how metering error turns into scrap across machine types.

One cup check proves the machine delivered that ratio, for that component pair, at that output, for that duration. It does not prove the ratio holds at a different output, or that the next material lot behaves the same way. Record the conditions with the result so a later comparison means something.

a17

A Worksheet for Your Own Line

Six inputs cover most of the calculation, and only one of them is optional.

Input Where to get it Required or optional What it changes
Parts ratio by weight, with the order and basis stated Data sheet plus your formulation record Required The denominator and which pump receives which share
Target total output at the mixing head Shot weight and line takt Required Both component mass flows
Component density at tank temperature Measured at process temperature Required for volumetric machines Volume ratio and pump setting
Highest and lowest output you actually run Production schedule Required Small-component pump sizing and turn-down
Measured component flows at two output settings Cup weight test Required Confirms the calculation matches delivery
Shot record trend across shifts Machine log Optional Early warning of drift and meter error

To run the calculation for a new line:

  1. Confirm the ratio order and basis from the data sheet, and write the parts next to each component name rather than relying on the sequence.
  2. Divide each part by the parts sum to get the fraction, then multiply by the target total output to get each component’s mass flow.
  3. Divide each mass flow by the density measured at tank temperature to get the volumetric flow, then compare that with pump displacement and stroke rate.
  4. Check the small component’s flow against the lowest flow its pump can control, not against its rated range.
  5. Run the cup check at the highest and lowest output and record both results with the material lot number.

The worksheet does not decide the ratio. It tests whether the machine can deliver the ratio the formulation needs at the output the schedule requires. When the answer is no, the options are a different pump size, a lower maximum output, or a formulation change, and that decision belongs with the material supplier and the equipment supplier together.

a19

Send Your Ratio and Output Before You Commit to a Pump Size

If you are sizing a machine or checking whether an existing one can hold ratio at your lowest output, send the parts ratio by weight and the order it is written in, the total output in grams per minute at both your highest and lowest settings, the density of each component at tank temperature, the smallest shot you run, and the pump models currently on the line. Those five inputs are usually enough to say whether the small component stays inside its controllable band, or whether the output range should be split across two machines.

Haifeng Polyurethane Machinery reviews metering configurations against these figures before quoting a pump size. Email info@haifeng-automation.cn or send the same list on WhatsApp to 86 13566296633.

FAQ

Is mixing ratio the same as isocyanate index?

No. Mix ratio by weight describes how much of each component the machine must deliver, written as parts of one component against parts of the other. Isocyanate index describes the ratio of actual NCO groups to the theoretical stoichiometric requirement for that formulation. A formulation running at index 105 still has a fixed mix ratio by weight for a given polyol and isocyanate; change the polyol’s hydroxyl value and both the index and the weight ratio move. Convert between them with formulation data, not with a machine setting.

Should I calculate flow rates by weight or by volume?

Calculate by weight first, because the formulation and the mix ratio are defined by mass, and mass is what a scale can verify. Convert to volume only when you need to set a volumetric pump, choose a displacement, or compare against a flow meter reading. The conversion needs density at process temperature, and that value changes as material warms or as filler settles. Machines that accept a weight ratio and control it in closed loop remove the conversion step, but the cup check still happens on a scale.

Why does my ratio drift when I lower the total output?

Because several error sources are fixed in absolute terms while the small component’s flow is not. Check valve leakage, pump slip and mixing head dead volume remove roughly the same number of grams per minute at any output, so their share of the small component’s flow grows as that flow falls. A 3 g/min loss is 4 percent of a 74.5 g/min isocyanate flow and 16 percent of an 18.6 g/min flow. Below a certain output the pump also stops controlling its own delivery, so the fix is usually sizing rather than adjustment.

How do I check the real ratio without a flow meter?

Purge each component separately into a tared container for a fixed period at a stable production setting, weigh both samples, and convert each to grams per minute. The measured ratio is the ratio of the two mass flows. Run the same test at your lowest output, because a ratio that holds at 240 g/min may not hold at 60 g/min. Repeat after material lot changes and pump service. A combined shot weight is faster but only confirms the total, so it cannot reveal an inverted or drifted split.

If you’re interested, check out these related articles:

Cost of a Tire Foam Filling Machine
Advantages of Polyurethane Safety Shoes
Foam Filled Tires vs Solid Tires
Roof and Wall Sandwich Panel Production Line: Machine Selection for Industrial Buildings