Cavitation in polyurethane metering pumps rarely shows up as a hole in a pump body. It shows up as a ratio that walks away at the end of a shift, a crackle from the pump head at high output, or a run of parts with gas trapped under the skin. The reflex is to blame the pump. In most metering faults I have been called in on, the pump was doing exactly what it was told, with a fluid that had already lost pressure or already released gas before it reached the inlet. Those two possibilities have to be separated first, because they are fixed with different hardware. This guide works from the tank outward rather than from the pump inward.
What Cavitation Actually Does Inside a PU Metering Pump
A liquid arrives at the pump inlet at some absolute pressure. Where local pressure falls below the level at which the liquid’s own vapor forms, or below the level at which dissolved gas leaves solution, bubbles appear. They grow while pressure stays low and collapse where pressure recovers, which is usually inside the pump and immediately downstream of it. Each collapse concentrates energy into a very small area of metal. Over hours and days, that removes material.
Polyurethane metering makes the process harder to see in three ways. First, the fluids are viscous, so a bubble that forms in a polyol line does not rise out of the stream; it travels with it. Second, a metering pump is positive displacement, so gas occupies volume that should have been polymer. The pump loses mass throughput, not just pressure, and the A:B ratio shifts without any change to the pump setting. Third, polyol and isocyanate do not release gas to the same degree, so one side of the machine loses more volume than the other and the error appears as a formula problem rather than a pumping problem.
| What you observe | Cavitation signature | Other cause that looks similar | Do not infer |
|---|---|---|---|
| Output falls short at high rate but recovers at low rate | Inlet budget shortfall, scaling with speed | Worn pump internals, partially blocked discharge filter | Do not call the pump worn until inlet pressure is measured at the worst case |
| Crackle or rattle from the pump head | Gas pockets collapsing, often intermittent | Loose coupling, bearing wear, relief valve chatter | Noise by itself does not prove cavitation |
| A:B ratio drifts during a run | Unequal gas release on the two components | Calibration drift, temperature change, internal slip | A ratio correction does not remove the gas source |
| Pitting on the inlet side of gears or plunger | Erosion where pressure recovers | Abrasive filler wear, which is broader and smoother | Do not replace the pump before the gas source is identified |
| Bubbles under the skin of the part | Gas carried through the mixing head | Moisture reaction, or air folded in at the mixing head | Surface bubbles at the gate are different evidence from distributed bubbles |

The practical consequence is that a ratio correction made at the control panel is the wrong response to a gas problem. Recalibrating against a gas-loaded pump restores the numbers for a while and leaves the erosion running.
A drifting ratio invites a calibration correction, but recalibrating against a gas-loaded pump only hides the fault until the next drum. <PU Foam Injection Machine: Key Components & Calibration Best Practices> covers how machine components and calibration steps are sequenced when metering hardware is being verified.
Vapor Cavitation and Gas Cavitation Need Different Fixes
Treat this as the two-source rule. Before any hardware is touched, decide whether the bubbles come from the fluid boiling or from gas entering and leaving solution. Both produce similar noise and similar damage, and both are commonly called cavitation, but the evidence that confirms each one is different and so is the repair.
Vapor cavitation
Vapor cavitation means the fluid itself is boiling at the pump inlet. It requires the inlet pressure to sit at or below the fluid’s vapor pressure at the working temperature. Polyol and polymeric MDI both have very low vapor pressure at normal processing temperatures, so a healthy machine rarely vapor-cavitates on those materials alone. The realistic exceptions are hot material, a strong degassing vacuum on the supply tank, and volatile isocyanate grades. TDI carries noticeably more vapor pressure than polymeric MDI at the same temperature, so a heated TDI line running under vacuum deserves its own review rather than a copy of the MDI settings.
Gas cavitation
Gas cavitation means the pump is handling gas that is not the fluid’s vapor. There are three sources, and they leave different traces. Entrained air enters through the tank, usually from a return line discharging above the liquid level or an agitator running fast enough to fold air into the batch. Dissolved gas comes out of solution when pressure falls, well before the fluid would boil, which is why a vapor-pressure margin alone does not protect the pump. Carbon dioxide is generated inside the isocyanate itself when moisture reacts with it, and it announces itself with haze, fine sediment, and a fault that returns on the same pump after every drum change.
The discrimination step matters more than any single instrument. A suction line runs below atmospheric pressure. A leak in it admits air inward and never weeps liquid outward, so a visual inspection of the suction side proves nothing about whether it is tight. That single fact explains why gas cavitation survives so many reports that the pipes were checked.
Build the Inlet Pressure Budget Before You Change Any Hardware
Write the budget as one line and the argument usually ends there:
available inlet pressure = tank pressure + static head − suction line loss − strainer loss − acceleration loss
Tank pressure is the starting point. It is atmospheric on a simple day tank, higher on a pressurized vessel, and well below atmospheric on a tank pulled down for degassing. Static head is the height of liquid above the pump inlet, and it falls through the shift as the tank empties. Suction line loss is friction in the pipe, hose and fittings, and it rises with viscosity and with flow. Strainer loss climbs as the element loads. Acceleration loss is the extra demand created each time a piston or a gear pocket refills, and it is the term most often left out because it never appears on a pipe sizing chart.
| Term | What it contributes | How it gets ignored |
|---|---|---|
| Tank pressure | Starting pressure, atmospheric, pressurized or under vacuum | Vacuum is set by the degassing requirement and never compared with pump needs |
| Static head | Height of liquid above the inlet | Tank level drops through a shift and takes the margin with it |
| Suction line loss | Friction in pipe, hose and fittings | Sized once at commissioning, never revisited when output is raised |
| Strainer loss | Restriction that grows as the element loads | A clean element at start-up is assumed to stay clean |
| Acceleration loss | Refill demand on every pump cycle | Not calculated for positive displacement pumps at all |

The acceptance condition is not one number. The available inlet pressure has to stay above the fluid’s vapor pressure by a working margin and above the pressure at which dissolved gas comes out of solution on that material. The second threshold is often the binding one, and it is material and temperature specific, which is why the same machine can cavitate on one polyol and run clean on another.
An illustration makes the arithmetic visible. Take a polyol at 1100 kg/m³ drawn from an atmospheric tank with 0.8 m of liquid above the inlet. Static head contributes about 8.6 kPa. At 60 L/min through a 25 mm line with four elbows and a partly loaded strainer, friction and strainer loss can consume 15 to 25 kPa, and a piston pump adds acceleration loss on top of that. The margin is thin before anything is wrong. Now pull 300 mbar absolute on that tank for degassing and the starting pressure falls from about 101 kPa to about 30 kPa. The pump has not changed. The budget has lost roughly 70 kPa. These figures illustrate the arithmetic only; they are not a recommended setting for any specific line.
Why a Degassing Vacuum and a Starving Pump Can Share the Same Tank
Vacuum degassing and pump inlet pressure pull in opposite directions, and they are usually specified by two different people. The process engineer wants deeper vacuum because it removes more dissolved gas and improves cell structure. The pump sees that same vacuum at its suction and loses most of its pressure budget. Neither specification is wrong on its own. The conflict appears when the two are never compared.
There are several ways to resolve it, and they trade off differently. Reducing the vacuum to the minimum that still meets the deaeration requirement is the cheapest move, but it may not be enough for a demanding foam. Raising the tank or raising the liquid level in it adds static head at no energy cost, though structural limits often cap it. Enlarging and shortening the suction line buys back friction loss and is almost always worth doing, at the price of more material held in the line and a larger flush volume at changeover. Fitting a transfer pump between the degassing tank and the metering pump is the most complete answer, because it lets the tank run at whatever vacuum the process wants while the metering pump receives a positive inlet pressure.
That transfer pump needs its own review. It draws from the same vacuum tank, so its inlet condition is worse than the metering pump’s was, and it will cavitate first if it is selected on flow and discharge head alone. A transfer pump that runs too fast also tends to re-entrain air at its own inlet, which reintroduces the problem downstream.

Match Pump Type, Speed and Line Size to the Material
Pump selection decides how much inlet margin the machine needs before any other choice is made. The same duty can be met by several geometries, and each one responds to gas and to viscosity differently.
| Pump type | Strength | Watch | Fits |
|---|---|---|---|
| External gear | Compact and precise at moderate pressure | Slip rises as viscosity falls or clearances wear, and gas destroys volumetric efficiency unpredictably | Unfilled polyol and isocyanate at steady temperature |
| Piston or plunger | High ratio precision | Pulsating suction demand raises acceleration loss and needs more inlet margin | Elastomer casting and high-pressure metering |
| Screw | Smooth flow, low pulsation, tolerant of low inlet pressure | Ratio precision depends on speed stability | High-viscosity and filled systems |
| Diaphragm | Sealed, with no shaft seal path for air ingress | Suction valve wear quietly reduces fill | Small-flow additive and color lines |

Speed is the variable most often left on the table. A larger pump running slower moves the same output with lower acceleration loss, less shear and less gas release per unit of time. The cost is money and floor space, and on filled systems a slower pump also wears less. If a machine cavitates only when it is pushed to its rated maximum, the honest conclusion is usually that the maximum is a brochure rating rather than a continuous operating point.
Line design follows the same logic. Keep the suction run short, with few fittings, and prefer rigid pipe or a reinforced hose to a plain suction hose, because a hose can collapse partly on the inside while looking perfect on the outside. Put a coarse strainer on the suction side and fine filtration elsewhere in the circuit, since a fine suction element spends its life consuming the margin it was meant to protect.
Temperature sits underneath all of this. Warming a polyol lowers its viscosity, which reduces line losses, but it also raises vapor pressure and speeds gas release. On isocyanate the effect is stronger still. A machine that runs clean cold and faults hot is telling you which side of that balance it is on.
Pump geometry sits inside a larger machine architecture, and the way the two components are stored, conditioned and delivered changes what the pump sees at its inlet. <How Polyurethane Foam Machines Work: Types and Applications> covers the main machine types and where each one is normally applied.
Metering accuracy figures only hold when the pump stays full. On the LJJ series low-pressure foaming machine, Haifeng specifies a metering accuracy of plus or minus 0.5 percent using high-precision metering pumps and closed-loop flow control, and that number is conditional on the inlet condition being maintained. A pump rated to that accuracy will not deliver it while it is handling a mixture of polyol and gas.
A Symptom-to-Cause Check List for the Shop Floor
Work in this order, because it moves from cheap evidence to expensive change.
- Record the exact condition where the symptom appears: output rate, material temperature, tank level and vacuum setpoint. A fault that only appears at the end of a shift has already told you it is a pressure budget problem.
- Fit a compound gauge at the pump inlet and read it at the worst case, not at idle. A gauge at the tank outlet measures the tank, not the pump.
- Raise the tank level, or temporarily reduce the degassing vacuum, and repeat the run. If the symptom disappears, the budget is short. If it stays, look for air ingress or gas generated in the material.
- Pressure-test or isolate the suction line. A vacuum-side leak draws air inward and never shows as a weep, so a dry joint proves nothing.
- Check strainer differential pressure and inspect the suction hose for internal collapse.
- Check isocyanate quality last but not least: haze, sediment and water content against the supplier data sheet, and verify that drum handling and blanketing have not changed.
| Check | What it establishes | Required or optional | Do not infer |
|---|---|---|---|
| Inlet pressure at worst case | Whether the budget closes at all | Required before any hardware change | A gauge at the tank outlet is not the pump inlet pressure |
| Tank level and vacuum log | Whether the symptom tracks the budget | Required | One good reading does not cover the end of a shift |
| Suction line pressure test | Whether air is being drawn in | Required when the symptom is independent of output rate | A joint that does not weep is not proven tight under vacuum |
| Strainer differential pressure | Whether the element is consuming the margin | Required | A clean element at changeover does not predict its loading rate |
| Isocyanate haze, sediment and water | Whether CO2 is being generated in the material | Required when the same pump repeats the fault | A clear sample from the top of the drum is not proof for the whole drum |
| Pump speed reduction trial | Whether the fault scales with speed | Optional diagnostic | A quieter pump is not a fixed pump |

Send the Suction Details Before You Change the Pump
Most cavitation calls are settled on paper, before a single component is swapped, once the inlet condition is written down. Send the polyol and isocyanate viscosity at pumping temperature, tank pressure and whether it is atmospheric or under vacuum with the setpoint, static head above the pump, suction line bore and length with fitting count, strainer mesh, pump type and displacement, required output per shot, and filler content if any. With those numbers the pressure budget can be checked against the material data, and the answer is usually clear about whether you have an inlet problem or a pump problem. Haifeng Polyurethane Machinery builds low-pressure and high-pressure metering systems and turnkey lines, and we will say plainly which one your symptom belongs to. Email info@haifeng-automation.cn or message WhatsApp 86 13566296633.
FAQ
Is cavitation always caused by a blocked suction filter?
No. A loaded strainer is one contributor to the pressure budget, and it is the easiest one to check, which is why it gets blamed first. A clear strainer tells you the element is not the restriction; it says nothing about vacuum-side air ingress, dissolved gas released at low pressure, or carbon dioxide generated in the isocyanate by moisture. If the symptom is unchanged after a fresh element, stop working on the filter and measure inlet pressure at the worst case instead.
Can I simply slow the pump down to stop it?
Sometimes, and it is a useful diagnostic. Reducing speed lowers acceleration loss and reduces the volume of gas released per unit of time, so a fault that fades as speed drops is likely a budget problem. But slowing the pump costs output, and it will not fix air drawn through a leaking suction joint or CO2 formed inside the isocyanate. Use the speed trial to confirm the mechanism, then correct the cause rather than accepting a permanently derated machine.
What does cavitation damage look like inside a gear pump?
Expect pitting and material loss concentrated on the inlet side of the gear teeth and on the bearing faces, with a rougher, more localized pattern than you would see from abrasive fillers. Filler wear tends to be broader, smoother and distributed across the loaded surfaces, often with a polished appearance. Location matters as much as appearance: erosion where pressure recovers downstream of the inlet is the signature to look for before you conclude the pump was simply worn out.
Does a vacuum degassing tank increase cavitation risk?
Yes, and the effect is large. Pulling the tank to a few hundred millibar absolute removes most of the pressure the metering pump had to work with, even though nothing about the pump has changed. The usual resolutions are to run the minimum vacuum that still meets the deaeration requirement, raise the liquid level, shorten and enlarge the suction line, or fit a transfer pump so the metering pump receives a positive inlet pressure while the tank stays under vacuum.
If you’re interested, check out these related articles:
Glass Wool Sandwich Panel Production Line: Applications, Advantages and Production Challenges
Fully Automatic Rain Boot Production Line Guide
How to Choose a PU Shoe Injection Machine
What Is a Polyurethane DIP Machine for Safety Shoes