Most ratio arguments on a polyurethane line begin with two numbers that were never measured the same way. The controller shows 100:45, a gravimetric check returns 100:47, and an in-line flow meter reports a third figure. None of the three is wrong. Gravimetric, flow-meter and volumetric calibration each measure a different quantity at a different point in the flow path, so they answer different questions about PU metering accuracy. The working hierarchy is straightforward: a gravimetric catch is the reference, an in-line flow meter is a continuous monitor that depends on that reference, and a volumetric check is a fast screen for gross faults between formal verifications.
What Each Calibration Method Measures in a PU Metering System
Every PU metering system follows the same chain: day tank, metering pump, filter and valves, mixing head, then mold or open pour. A calibration method is defined by where it taps that chain, and the differences below follow from that single fact.
| Method | Where it measures | Quantity reported |
|---|---|---|
| Volumetric | At the pump, before valves and any leakage path | Volume per revolution or per stroke |
| Flow meter | Downstream of the pump, upstream of the mixing head | Mass flow, or volume flow that still needs density |
| Gravimetric | At the dispense point | Mass per unit time, then ratio by weight |
The ratio basis matters as much as the method. Most PU material data sheets state the component ratio by weight, typically in the form of polyol 100 to isocyanate 45 or similar, while the machine recipe often stores a volume ratio derived from densities entered during commissioning. A machine holding a correct volume ratio can still deliver the wrong weight ratio if those density inputs do not match the temperature at which the material is actually metered. That single conversion error explains a share of the reports where a machine appears to drift overnight after a material change, with no pump or valve touched.
Machine architecture also decides which measurements a plant can take at all. A low-pressure machine with a dynamic mixing head and calibration ports can dispense each component separately into its own container. A high-pressure impingement head has to be flushed and bypassed before a clean single-component catch is possible. On lines where only mixed material can be collected, a total mass output check is still available, but a component ratio cannot be separated from that sample.

The metering and mixing sections differ between machine types, and so does the point where a calibration sample can be taken. <How Polyurethane Foam Machines Work: Types and Applications> covers the machine categories and how their metering and mixing sections are arranged.
Why the Three Methods Disagree on a Healthy Machine
Four mechanisms explain most disagreements, and only one of them involves a worn part.
Ratio basis is the first. A weight ratio converted to volume using a density at the wrong temperature is a systematic offset, not random scatter, and it repeats on every check.
The measurement point is the second. Volumetric counting stops at the pump. Gravimetric weighing starts at the nozzle. Everything between those two points, including internal leakage, valve lag and dribble, appears in one number and is invisible in the other.
Entrained air is the third. Polyol that has been recirculated or handled under low pressure can still carry fine bubbles. A pump displaces less liquid volume per revolution when gas occupies part of the chamber, so the volumetric reading falls. The mass on the scale barely changes, because the gas contributes almost nothing to it. On that day the volumetric and gravimetric results part company, and only the mass figure describes what the mold received by weight.
Valve timing is the fourth. The A and B valves do not open and close at the same instant. A 50 ms lag inside a six second shot is a small share of the total. The same lag inside a 1.5 second shot distorts the ratio substantially, which is why short shots and small molds often show worse ratio records than long ones on identical pumps.
| Record | What it establishes | Do not infer |
|---|---|---|
| Gravimetric catch, 30 s at production temperature, 100:45.4 by weight on a calibrated scale | Weight ratio at that setting, that material lot and that temperature | That the controller’s stored volume ratio is correct, or that the same ratio holds at a different output |
| Coriolis reading across a 6 s shot, 100:45.0 ±0.5% | Mass flow at the meter’s location during that shot | That the mold received that ratio, since valves and the mixing head sit downstream of the sensor |
| Volumetric dispense, 20 strokes per side, equal cylinder levels | Similar displaced volume at that back pressure and temperature | That the weight ratio matches the data sheet when densities or material temperatures differ |
| Data sheet claim, metering accuracy ±0.5% | A specified result under the maker’s test conditions | Plant accuracy at minimum output, with a different viscosity, or after seal and check-valve wear |
These records belong to different measurement points and different test conditions. A purchase specification quoting a tight accuracy figure is a claim about a defined test, and the plant still has to establish what the same machine holds at its own usual output and temperature.

Gravimetric Calibration as the Reference Method
Gravimetric calibration earns the reference position because it measures mass where the material leaves the machine and needs no density input to produce a weight ratio. That removes the conversion step that causes many of the disputes described above.
Running a gravimetric catch that holds up
- Bring the machine to production conditions: tank temperatures, recirculation and the output range the line actually runs.
- Route each component to a separate, clean and dry container. Use the calibration ports or a bypass at the mixing head where the machine provides them.
- Tare the container, dispense for a machine-timed interval, then weigh immediately. Record the interval, the gross and tare masses, and the material temperature.
- Repeat for the second component at the same interval and conditions.
- Compute mass flow for each side, then express the ratio in the same basis the material data sheet uses.
- Correct the ratio factor or pump speed, then confirm the result at production output and again at the low end of the range, where slip and valve timing have the largest relative effect.
Where gravimetric checks still lose precision
Scale resolution limits the result before anything else does. If the balance resolves 0.1 g and the catch weighs 200 g, resolution alone contributes roughly 0.05% to each reading, which is acceptable against a one percent ratio tolerance and marginal against a tighter one. Doubling the catch time buys resolution and costs production time, so the interval should be chosen against the tolerance rather than copied from a template.
Traceability of the balance is a separate question from the quality of the procedure. A balance verified under OIML R 76-1 [1] and calibrated by a laboratory working to ISO/IEC 17025:2017 [2] gives an indication traceable to mass standards. That certificate does not validate the catch itself. Container tare drift, splashing, product left in the nozzle, and a temperature that moved during weighing all sit outside the certificate’s scope.
Two practical hazards deserve a place in the work instruction. Isocyanate reacts with ambient moisture, so catches need dry containers and quick handling. Polyol carrying bubbles weighs honestly, but it can foam in the container and make the tare unstable, which argues for a short settling time before the final reading.

Flow-Meter Calibration and Its Blind Spots
A Coriolis meter reports mass flow directly and is largely independent of viscosity and density within its specified range. Installation follows the guidance in ISO 10790:2015 [3] on selection, orientation and use, and the details that matter in practice are the ones that guidance covers: no gas trapped in the measuring tube, adequate straight runs, and a zero taken at process temperature and pressure rather than on a cold machine. A volumetric meter, whether gear, oval-gear or turbine, adds a K-factor that shifts with viscosity, temperature and clearance wear, so its reading depends on more inputs than a Coriolis figure does.
What a flow meter adds to a calibration program
It turns calibration from an occasional event into a per-shot record. Ratio can be logged for every shot, drift inside a single shot becomes visible, and a closed-loop machine can correct the ratio while it runs. This is where flow metering pays for itself on lines with many short shots, where a monthly catch would miss most of the variability.
What a flow meter cannot tell you
The meter sits upstream of the mixing head and of any downstream valve. A partially blocked or slow-closing valve leaves the meter reading correctly while the mold receives less material, and no amount of meter precision changes that. The meter’s own drift is equally invisible without an independent reference, because a sensor that has shifted reads consistently wrong and therefore looks stable.
Haifeng’s LJJ series low-pressure foaming machine illustrates the useful version of this arrangement, with metering accuracy specified at ±0.5% and closed-loop flow control on the metering pumps. That figure describes the machine’s performance under defined conditions. Confirming what the head actually delivers at a plant’s own temperature and output still requires a gravimetric catch, and the closed loop is only as good as the feedback element it depends on.

High-pressure machines mix by impingement, so the metering figure that matters is the one held at the mixing head rather than at the pump outlet. <High Pressure PU Foam Machine: Technical Specifications & Industry Applications> covers the specifications and application scope of high-pressure PU foam equipment.
Volumetric Calibration as a Fast Screen
Volumetric calibration counts what the pump is commanded to displace. On a gear pump that means displacement per revolution multiplied by shaft speed; on a piston pump it means nominal stroke volume multiplied by stroke count. A practical check costs minutes: dispense each component into a graduated cylinder for a fixed number of strokes or a fixed time, compare the levels, and convert with density if a weight ratio is needed.
The strength of this method is speed and early warning. It catches a wrong recipe, an air lock on the suction side, a blocked filter, a pump running at half speed, or a gross seal failure before the first part is poured. Used at shift start, it closes the gap between formal calibrations without consuming production time.
Its ceiling is equally clear. Stroke count and shaft speed describe commanded delivery, not delivered mass. Internal leakage across a worn check valve, slip that rises with back pressure, and a temperature difference between the two components all sit outside the measurement. Volumetric ratio is also temperature dependent: both components expand as they warm, and they do not expand identically, so a volume ratio confirmed at 25 °C is a different weight ratio at 40 °C.
On a forgiving product with a wide ratio window, that ceiling may never be reached. On color-critical shoe soles or tight-tolerance automotive parts, a volumetric check is a screen and nothing more.

Low-pressure machines meter through gear or piston pumps, which is why displacement checks feel reliable until slip and leakage enter the picture. <Guide to Low-Pressure Foaming Machines for PU Elastomers> covers low-pressure foaming equipment used in PU elastomer processing.
Matching the Method to the Decision
The method should follow the question being answered, not the other way around. A plant that runs one method for every purpose usually ends up with records that cannot support the decision it actually faces.
| Decision | Method that answers it | Do not use it when |
|---|---|---|
| Setting the ratio for a new material lot | Gravimetric catch at production temperature | The catch mass you can afford is too small for the balance to resolve the tolerance |
| Watching every shot in production | In-line Coriolis meter with periodic independent reference | The meter has no recent reference check, or its reading has moved without explanation |
| Shift-start screening | Volumetric dispense into a graduated cylinder | You need to certify a weight ratio to a fraction of a percent |
| Investigating a drift or defect complaint | Gravimetric catch plus meter trend over the same period | You hold only one record at one output setting |
Frequency follows change, not the calendar. A new material lot, a pump or seal rebuild, a flow-meter replacement, a ratio alarm, a defect investigation and the start of a new mold are the events that make a fresh catch worth the hour it costs. Where the product tolerance is tight and the line runs continuously, a fixed interval on top of those triggers is defensible, and the drift history should set it.
Keep bias and repeatability separate when reading the results. Three catches at one setting show spread, and their average shows bias against the data sheet. Averaging scattered readings does not correct a systematic offset; it only hides the scatter.
Records, Drift Limits and Acceptance Criteria
A drift limit should come from the product, not from the machine’s resolution. Identify the property that fails first when the ratio moves, whether that is density, hardness, color or cell structure, then find the ratio offset at which that property leaves its window. Set the alarm at a fraction of that offset so drift is caught while the parts are still saleable.
The record needs enough detail to be re-read a year later: date and shift, operator, material lots for both components, tank and material temperatures, pump speed or output setting, catch interval, gross and tare masses, computed ratio and basis, balance identification with its calibration due date, meter readings for the same period, and the action taken. ISO 9001:2015 clause 7.1.5 [4] requires monitoring and measuring resources to be fit for purpose and controlled, which is what these fields support. The certificate behind the balance supports resource control; it does not by itself prove that any particular ratio was correct on the floor.
Review the limits whenever the inputs change: a new polyol or isocyanate grade with a different density or reactivity, a change of curative, a pump or mixing-head overhaul, a re-ranged flow meter, or a move to a lower output range where the same absolute leakage is a larger share of the flow.
Plan a Calibration Step That Fits Your Line
Send the polyol and isocyanate types in use, the data sheet ratio and whether it is stated by weight or by volume, your output range from minimum to maximum, the metering principle on the machine you run or intend to buy, the tolerance the product allows, and the records your quality system requires. Those inputs decide whether a gravimetric reference, an in-line meter or a volumetric screen belongs in your routine, and in what order they should be applied. Haifeng Polyurethane Machinery can review the metering configuration against them and confirm what the equipment is specified to hold. Email info@haifeng-automation.cn or reach WhatsApp on 86 13566296633, and include the ratio basis with the material data rather than treating the controller’s displayed ratio as a measurement.
FAQ
Is gravimetric calibration more accurate than a flow meter?
Not automatically. Accuracy depends on catch mass against balance resolution, the stability of material temperature during dispensing, and whether the components can be caught separately. A short catch on a coarse balance can be less reliable than a maintained Coriolis meter with a recent reference check. Gravimetric keeps the reference role in most plants because it measures mass at the point of use and needs no density input to express a weight ratio.
How often should a PU metering machine be calibrated?
Tie the interval to change and to product sensitivity rather than to a fixed calendar. A new material lot, a pump or seal rebuild, a meter replacement, a ratio alarm, a defect investigation and a new mold all justify a fresh catch. Where the ratio window is narrow, add a fixed interval and let the drift history set it; a stable line with a wide window can run longer between full gravimetric checks if volumetric screening happens at shift start.
Can the ratio displayed on the HMI be trusted?
It is a computed value. On a volumetric machine it comes from pump speed and stored densities; on a closed-loop machine it comes from flow-meter feedback. Both are only as good as those inputs. Compare the display against an independent gravimetric catch at production temperature and record the difference, then decide whether the display needs correction or the machine needs service.
What ratio tolerance should a line hold?
Start from the material data sheet and from the property that fails first in your product. If color or hardness leaves its window well before the data sheet tolerance is exhausted, work to the tighter of the two. A ratio window narrower than the process needs drives over-correction, longer changeovers and avoidable waste, while a loose window hides drift until the scrap appears in final inspection.
References
[1] OIML R 76-1:2006, “Non-automatic weighing instruments. Part 1: Metrological and technical requirements. Tests,” International Organization of Legal Metrology, 2006.
[2] ISO/IEC 17025:2017, “General requirements for the competence of testing and calibration laboratories,” ISO, 2017.
[3] ISO 10790:2015, “Measurement of fluid flow in closed conduits. Guidance to the selection, installation and use of Coriolis flowmeters,” ISO, 2015.
[4] ISO 9001:2015, “Quality management systems. Requirements,” ISO, 2015.
If you’re interested, check out these related articles:
High Pressure PU Foam Machine: Technical Specifications & Industry Applications
Polyurethane Foam Spraying Machine: Robot-Assisted Precision Spraying Systems
Polyurethane Foam Machine Types: The Scrap Cost of Inaccurate Metering
High Pressure PU Foaming Machine for Car Seats & Steering Wheels: A Production Setup Guide