Tank Agitation Design for Polyol and Filled PU Systems

Tank agitation design for polyurethane processing starts with a question that rarely appears in an equipment quotation: what is this stirrer supposed to change? In a metering day tank the answer is usually one of three jobs, holding a temperature-uniform body of polyol so the viscosity at the pump inlet stays constant, keeping a filled or graft polyol in suspension, or slowly melting and homogenising an isocyanate that has crystallised. Each job implies a different impeller, a different speed and a different control logic. Fitting the same slow paddle to all three produces the familiar complaints: ratio drift on a cool morning, filler settling overnight, and a polyol that foams every time the tank is topped up.

Which PU streams actually need agitation

A metering machine does not see the average of the tank. It sees the material at the pump inlet, and a volumetric pump turns whatever viscosity it meets there into flow. When the lower half of a day tank sits a few degrees cooler than the top, the pump meters a thicker material than the recipe assumes, and the error appears in the shot record as drift. The first response is often to recalibrate a pump that was never out of calibration.

Agitation prevents that, and it also creates a second problem when the same solution is applied to every stream. A low-viscosity isocyanate and a heavily filled polyol are not the same fluid, and they do not want the same tank.

Stream Usual need Risk if under-agitated Risk if over-agitated
Unfilled polyether polyol Continuous slow bulk turnover Temperature stratification, cool layer at the wall Air entrainment, vortex at the pump inlet
Graft polymer polyol Continuous low-shear motion Settling of the dispersed phase, agglomerates Foaming, damage to the dispersion
Filled polyol with calcium carbonate, barium sulfate or glass fibre Continuous, or a defined period before use Hard settled layer, density and hardness variation Fibre breakage, impeller wear, entrained air
Polymeric MDI Minimal, driven by temperature Crystallisation at cold spots, stratification Moisture pick-up, entrained gas, urea solids
Solid MDI grades Slow motion during melting only Unmelted solids drawn to the pump Local overheating, fume at the hot wall

a1

TDI is the clearest case for fitting nothing. It arrives as a low-viscosity liquid, it is already homogeneous, and it is the stream most sensitive to water. An agitator on a TDI tank adds a seal, a motor and a moisture path in exchange for no measurable gain in uniformity. Temperature control and dry blanketing are where the money belongs.

Recirculation is not the same thing as agitation, although quotations often use the two words interchangeably. A recirculation loop moves material out of the tank and back again, which is effective for temperature control and for keeping a filled stream in motion. It does little for the wall layer at the top of a tall tank, and it adds shear at the pump. Most workable installations use both: a slow agitator for bulk motion, and a loop for heat and transfer.

What agitation has to achieve in a metering day tank

Four jobs matter, and one of them is a thing to avoid.

Temperature uniformity drives ratio stability. Polyol viscosity changes quickly with temperature, and a pump that repeats to a fraction of a percent will still deliver a different mass flow when the viscosity at its inlet shifts. The wall layer is the usual culprit. Heat leaves through the tank wall, the material beside it cools and thickens, and without bulk flow sweeping that layer the jacket control loop ends up fighting a stagnant film. Controllers that hunt on a jacketed polyol tank are often diagnosing an agitation problem.

Refill recovery is the second job. Material arriving from an IBC or a drum is usually colder than the tank contents and denser. Dropped into a warm tank it can sit as a layer at the bottom for a long time while a slow agitator stirs the top. The countermeasure is partly procedural: run the agitator for a defined period after a refill, and release the tank to production only when temperature readings taken low and mid-height agree.

Solids suspension is the third job, and in filled systems it decides most of the mechanical detail.

Air entrainment is the job that gets ignored. Any agitator that produces a vortex is also pumping air into the liquid. Air in a polyol reaches the mixing head, and in a filled system the bubbles stabilise against filler particles and reappear as voids in the casting. At the pump inlet the same air shows up as cavitation, which the machine reports as an unexplained flow fluctuation that no calibration removes.

a4

Choosing impeller type and flow pattern for polyol

For unfilled polyol the requirement is bulk flow at low shear. That points to an axial-flow impeller running slowly with a diameter that is large relative to the tank.

Axial flow suits most unfilled polyol

Hydrofoil and pitched-blade impellers move a large volume for the power they draw. An impeller diameter between roughly one third and one half of the tank diameter is a normal starting point for a low-viscosity stream, with the exact figure set by the vendor’s pumping curve and the required turnover. The speed should be low enough that the surface stays calm, and high enough that the material at the bottom of the tank is moving rather than waiting.

Baffles stop the tank from spinning

An unbaffled tank with a central agitator develops a rotating body of liquid that turns with the impeller. Mixing stops, power draw falls, and the vortex grows. Four vertical baffles, usually around one twelfth of the tank diameter in width and set off the wall, break the rotation and convert rotation into vertical circulation. A top-entering agitator mounted slightly off centre achieves part of the same effect in small tanks.

Viscous and filled service needs a different impeller

Impeller selection changes once the fluid gets thick. The agitation Reynolds number, density times speed times impeller diameter squared divided by viscosity, drops into the laminar range faster than most people expect for a filled polyol. In that regime a small axial impeller does not circulate the tank. It produces a local zone of motion around itself and leaves the rest still.

For laminar service the options are a close-clearance impeller such as an anchor or helical ribbon that sweeps the wall, several impellers on one shaft, or an external loop with a jet aimed along the tank bottom. The first also improves heat transfer, which matters whenever a viscous stream has to be warmed before it can be pumped.

a9

Isocyanate tanks need less agitation than most people fit

Crystallisation in MDI is a temperature problem, and stirring does not solve a temperature problem. Pure 4,4′-MDI is a solid at room temperature and common grades melt in the region of 40 °C, so the tank has to hold the material above its melt point with a margin taken from the data sheet rather than from habit. Melting a crystallised tank is slow work: the wall is warmed gently and the liquid moved slowly so heat reaches the solid without overheating the film at the jacket.

Agitation during melting exists to even out temperature, not to break crystals mechanically. A high-speed disperser concentrates heat at the shaft, can leave cold material against the wall, and disturbs the surface enough to raise vapour and moisture contact at the same time.

Water is the larger risk. Isocyanate reacts with moisture to form carbon dioxide and urea, and the result is sediment, rising acidity and blocked filters, followed by metering that will not repeat. Every design choice that increases contact between the liquid surface and ambient air moves the tank in that direction, including a vortex, an open hatch, a breather without a dryer and a worn shaft seal. That is why isocyanate tanks are normally run with a dry nitrogen or dried-air blanket and a calm surface, and why the seal on the B side deserves more attention than the agitator motor. A mechanical seal is a moisture path; a magnetic drive or a sealed bearing housing removes that path instead of managing it.

TDI needs even less. Viscosity is low, the material is homogeneous, and vapour control dominates the design. Closed transfer, temperature control and ventilation come before any question of stirring.

Keeping fillers suspended in filled PU systems

Settling velocity decides the design

Whether a filler stays suspended is a competition between how fast the particles fall and how fast the liquid around them rises. For fine particles in a viscous liquid, Stokes’ law gives the shape of the problem: settling velocity increases with the density difference between particle and liquid and with the square of particle diameter, and decreases as viscosity rises. Calcium carbonate at about 2.7 g/cm³ sitting in a polyol near 1.05 g/cm³ has enough density difference that settling is a matter of hours rather than weeks.

The plant has three levers. Temperature changes viscosity, so a cooler tank settles more slowly and pumps harder. Particle size distribution belongs to the material supplier. The third lever, the upward velocity produced by the agitator and the tank geometry, is the one the equipment specification controls.

Just-suspended is the target, not maximum turbulence

The standard criterion for a solids duty is the just-suspended speed, the minimum impeller speed at which no particle rests on the tank bottom for more than a moment. Below it, solids accumulate. Well above it, very little improves: the extra energy goes into air entrainment, impeller wear, and in glass-fibre systems into fibre breakage that quietly reduces the reinforcement the filler was added to provide.

Caverns form when the yield stress wins

Filled systems often behave as yield-stress fluids. Below a critical impeller speed the blade disturbs only a small cavern of material around itself while the rest of the tank stands still. The fault is easy to miss, because the shaft is turning and the motor is loaded. It surfaces as a hard layer after a weekend shutdown, or as a part that machines differently from the one produced before it.

Remedies include a larger impeller running more slowly, two impellers on one shaft, an off-bottom jet from a recirculation pump, or a conical bottom with a flush outlet. Dead legs, flat tank bottoms and long horizontal suction runs undo all of them, because they give the filler somewhere to settle that no impeller reaches.

a13

How to size agitator speed and turnover

Start from the working volume rather than the nominal tank volume, since the useful number is what sits between the low-level and high-level marks.

Turnover time is working volume divided by the circulation capacity of the impeller. Vendors estimate that capacity from a pumping number which depends on impeller type and flow regime, so ask for the pumping number and the resulting turnover at the quoted speed. A turnover figure offered without those two assumptions cannot be checked by anyone.

Turnover is a screening number, not a mixing guarantee. Two tanks with identical turnover but different baffling, diameter ratios and fill levels behave differently in service.

Tip speed is the shear number, calculated as pi times rotational speed times impeller diameter. It is the value to cap in a fibre-filled or shear-sensitive stream, and the value to hold constant when a design is scaled from a pilot tank to production.

Power draw scales with density, speed cubed and impeller diameter to the fifth power in turbulent flow. That relationship explains why a small speed increase costs a disproportionate amount of motor power, and why the same relationship stops being valid in laminar service. A scale-up calculation borrowed from a water trial does not describe a filled polyol.

Agitator power ends up in the fluid as heat. On a temperature-controlled day tank that input belongs in the jacket duty calculation; leaving it out produces a loop that holds setpoint on a quiet line and drifts once the agitator runs continuously.

Specify speed as a range with two documented limits, the minimum that keeps the stream homogeneous or suspended and the maximum that keeps the surface calm. A single fixed speed is a compromise chosen by the supplier rather than by the process.

Process parameters only hold if the material arriving at the pump matches the recipe they were written for. <Low Pressure PU Foam Injection Machine for Custom Molding: Process & Parameters> covers the process and parameter side of low-pressure injection for custom moulding.

Before any of those numbers carry weight, it is worth checking what the data in hand can actually support.

Record Method context Responsible use Do not infer
Supplier data sheet viscosity at 25 °C Rotational viscometer on a laboratory sample Comparing two grades and screening the impeller family The viscosity at tank temperature, or at the pump inlet after a weekend standing
A single viscosity value at one shear rate One instrument setting Estimating pump load in a Newtonian stream The behaviour of a shear-thinning filled polyol at impeller shear rates
A settling test in a one-litre sample Bench sample, short duration Ranking two fillers or two loadings The settled layer in a two-metre tank over a month of production
An agitator vendor’s turnover figure Vendor pumping number at a stated speed Comparing proposals that use the same assumptions That the tank is homogeneous; turnover measures bulk motion, not mixing quality

Where agitation design goes wrong

  1. A vortex nobody notices. The surface looks busy, which reads as effective mixing, while the impeller is drawing air into a stream that will later cavitate at the pump. Baffles and a lower speed remove the cause.

  2. Agitator discharge aimed at the pump inlet. Pushing flow straight into the suction creates pre-swirl and a pressure ripple that the metering pump converts into flow noise. A calming section, a baffle between impeller and outlet, or a repositioned outlet solves it.

  3. A stagnant wall layer and a hunting jacket. Heat transfer falls, the control loop overshoots, and polyol held against a hot jacket for long periods can discolour. Wall sweeping or adequate bulk flow is the fix.

  4. A seal that lets moisture into the B side. The leak is rarely visible; it shows up as sediment, rising acidity and filters that block sooner than they used to.

  5. Settling in the suction line rather than the tank. A long horizontal run and a low point give filler somewhere to collect, and no amount of agitation upstream clears it. Flush drains and short suction runs belong in the design.

Pump inlet stability is where a tank design becomes visible in the shot record. <PU Foam Injection Machine: Key Components & Calibration Best Practices> covers the key components and calibration practices that sit downstream of the tank.

Specifying agitation as part of the equipment package

The tank, the agitator, the heater and the metering pump are frequently three different suppliers, and the performance that matters belongs to none of them individually. Temperature uniformity, suspension and inlet stability are system properties. Writing them as a performance requirement with a check attached is the only way to keep them inside the scope of supply.

Field What to state Why it changes the design
Stream and grade Polymer family, isocyanate type, filler type and loading Settling, shear sensitivity and moisture risk all follow from it
Working volume and geometry Working volume, tank diameter, fill height, bottom shape, outlet position Diameter ratio, baffle sizing and dead-zone risk depend on these
Viscosity against temperature Viscosity at the lowest and highest tank temperature Decides laminar or turbulent service and therefore the impeller family
Temperature setpoint and tolerance Setpoint, permitted band, and the heat input from the agitator Sets jacket duty and whether wall sweeping is required
Suspension requirement Whether solids stay suspended continuously or only before use, and the acceptable settled layer Separates a just-suspended duty from an intermittent one
Agitation and control Impeller type, speed range, materials, seal type, interlocks Removes the supplier’s default single-speed compromise

A specification that reads “fit an agitator to keep the material homogeneous” cannot be accepted or rejected at commissioning, because it defines no condition. Replace it with two statements that can be checked: the stream stays within a stated temperature band at three tank heights after a stated standing period, and no free solids appear in a bottom sample taken before start-up. Vague wording survives into the contract and returns later as a dispute about what homogeneous was supposed to mean.

Commissioning checks that cost little and settle most arguments are a three-height temperature survey, a bottom sample for free solids, a surface inspection at maximum speed, an inlet pressure trace across a full shot, and a comparison of motor current against the nameplate value at the quoted viscosity.

One way to keep the responsibilities clear is to separate the jobs before the tanks are specified. In turnkey polyurethane lines built by Haifeng Polyurethane Machinery, the conditioning function often sits in a premixing or automatic filling station with its own slow agitator, recirculation pump and buffer volume, while the metering machine’s day tank holds a smaller working volume. The day tank then has less material to keep uniform and a shorter distance to the pump inlet, and its agitator can be sized for hold-up rather than for recovery from a bulk delivery.

Tank and agitator decisions usually get settled during turnkey scope discussions rather than as a separate purchase. <How to Build a Turnkey Sandwich Panel Factory: Machine Configuration, Layout and Investment Planning> covers machine configuration, layout and investment planning for a turnkey line.

What to send with an agitation enquiry

Agitation is easier to size from material data than from a tank drawing. Send the polymer family and grade, the isocyanate type, the filler type and loading, the working viscosity at the lowest and highest tank temperature, the working volume and tank diameter, the temperature setpoint and tolerance, whether the tank is blanketed, and where the metering pump suction sits. With those, an agitator can be selected against a stated duty instead of a tank size.

Haifeng Polyurethane Machinery builds metering machines and raw-material conditioning equipment, including premixing and automatic filling stations, as part of turnkey polyurethane lines. Email info@haifeng-automation.cn or send the same details on WhatsApp 86 13566296633, and the agitation and temperature-control arrangement can be reviewed together with the pump inlet layout.

FAQ

Does a polyol day tank need continuous agitation?

Not always continuous, but consistent. A small unfilled tank that turns over within a shift may hold temperature well enough with a short agitation cycle before production and a timer during long idle periods. Large tanks, tall tanks with a high wall-to-volume ratio, jacketed tanks running warm, and any tank receiving cold material from an IBC need continuous slow motion. The test is simple: read temperature at the top and the bottom after four hours of standing. A difference wider than the band the ratio assumes means intermittent running is not enough.

Can I agitate isocyanate to stop it crystallising?

Agitation helps during melting but does not prevent crystallisation. Crystallisation is driven by temperature, and the fix is holding the tank above the material’s crystallisation point with a margin taken from the data sheet, while avoiding cold spots on walls, glands and transfer lines. Once crystals form, warm the tank slowly and keep gentle motion so heat reaches the solid without overheating the liquid at the jacket. A high-speed agitator adds heat at the shaft and raises vapour and moisture contact, which works against the goal.

How do I know if my agitator is running too fast?

Watch the surface and the pump inlet. A visible vortex, a standing wave, or foam collecting at the wall means air is being drawn in, and the consequences appear downstream as cavitation, flow ripple and voids in filled parts. A second sign is motor current above the value recorded at commissioning without any change in level or viscosity. For shear-sensitive streams, glass fibre in particular, compare the mechanical performance of current parts against the original; broken fibre leaves no obvious trace on the tank.

Should agitation be a tank agitator or a recirculation loop?

Each does something the other does poorly. A tank agitator moves the whole body of liquid, sweeps the wall and keeps a low-viscosity stream uniform with little added shear. A recirculation loop gives strong temperature control, reaches places an impeller cannot, and is often the practical way to keep a heavily filled stream moving, but it adds pump shear and wear and does nothing for the layer at the top of a tall tank. Filled systems and large tanks usually need both.

What turnover should I specify for a filled polyol?

Turnover alone is not a specification for a filled stream. Two tanks with the same calculated turnover can differ completely in suspension performance, because impeller type, diameter ratio, baffling and bottom shape all change where the flow goes. Specify the result instead: no free solids in a bottom sample after the longest planned standing period, with a named maximum settled layer if some settling is accepted. Then check turnover and tip speed against the vendor’s pumping data to confirm the design can plausibly deliver it.